Tip Seal Kit for Ulvac Dry Vacuum Pump-DIS Series
Tip Seal Kit for Ulvac Dry Vacuum Pump-DIS Series
Couldn't load pickup availability
- Cost-down Routine Maintenance: The tip seal alternative is less costly compared with genuine one, tip seal service kit is a perfect replacement substitute for Ulvac DIS/DISL series dry scroll pump. Dry Scroll Vacuum pumps require routine maintenance and simple tip seal replacement to ensure the pump running under optimizing working condition; the tip seal is wearable parts, which require occasional purchasing. This service set is inexpensive with the same features and performance as genuine.
- Reliable and Excellent WorkingPerformance: Quiet running, low noise vibration, low wear, fitting the scroll groove seamlessly, preventing gas leaking and pump seizures. The tip seal set has been widely used and highly recognized by scientific labs, universities, medical or diaphragms research institutions and other application factories, helping them get the optimal vacuum Being available for the most DIS/DISL series, namely DIS-90/250/500.
- PTFE for Long Service Time: the foam backed tip seal is based on imported material Teflon (PTFE), taking advantage of its features for low wear,high extrusion, high temperature and good chemical resistance, precisely formulated by professional R&D team, innovative craftsmanship, thousands of on-site testing and practice, worry-free about the tip seal durability, more than 1 years performing lifetime.
- Easy to install and long guarantee: The quick and simple Ulvac tip seal replacement procedure just takes about less than half an house by professional and experienced personal. Pleasefollow the Instrument Manual or video on official website properly using proper personal protective equipment while working. 12 months guarantee, contact us for any inquiry or problem at any time.
- What you get:The tips seal kit is dark gray, light weight-160 gram/5.64 ounce. The package comes with a white box, including 2 piece of tip seal, long enough for the 4 scroll tip grooves, namely on the outboard housing, inboard housing, both sides of orbiting plate.
Package: including tip seal*2 pieces.
Applied to Ulvac scroll pump: DIS-90/250/500
Warranty: 1 Year
The Ulvac scroll dry pumps require routine maintenance and simple infrequently seal replacement, this procedure is important to prevent potential issues.
No equipment can be guaranteed perfect running without pump seizure. The tip seal is a critical but wearable part and require occasional replacement to keep the pump at optimal operating.
Our tip seals are exclusively formulated by professional RD teams and thousands of on-site testing and practice, have been used and recognized by scientific labs and instruments, research centers worldwide, can reliably serve scroll vacuum pump and reduce down-time and costly service expense. The alternative option is lower cost than genuine one, but the same performance as that.
Tips: 1. Follow the Quick Guide instructions available on official website to get a successful replacement.
- A tip seal replacement is easy to perform, takes about 30 minutes, and uses only common tools (not included).
- Run pump for about 40 hours (highly recommended) after finishing the replacement for optimum performance, as pumps with newly installed tip seals may require several days of operation to seat properly and achieve desired pressure and pumping speed.
To obtain warranty coverage, the defective item must be packaged and reached Cigram before the warranty expiration date in accordance with instructions provided with the Return Merchandise Authorization (RMA). Cigram Ltd has the sole authority to determine if a claim is covered by the limited warranty.
Note:
- We DO NOT accept free returns for certain circumstances.
- Once package reached you, check the package condition carefully, make sure no package damage or item defectives before opening box.
- If you found defectives, please contact us with pictures or videos for help.
Free Expedited Shipping
Secure Payment
- Worry-free Return

Frequent Asked
Why your tip seal looks different from genuine?
HONSVA tip seal kits are not the genuine, it is a substitute version for the original. Its performance is no less than the original tip seals, as they are taken by customers from ranges of scientific labs, RD centers, universities, manufacturers.
How long does tip seal typically last?
The tip seal is a critical but wearable parts for the pump, and require a routine maintenance, we highly suggested to check the tip seals and take a occasional replacement within a regular time interval, normally the 6-9 months.
Is it compatible with other pump models?
No! The original tip seals maybe compatible with other pump models under the same brand, while ours are NOT.
As we exclusively formulated it by PTFE, teflon, and varies for each models in length. Please check pump model before purchase this item.
Are there any special tools required for installation?
The tip seal replacement is easy to install with some small tools, such as Allen wrench, scour pad, low lint wipes, nitrile gloves, isopropyl alcohol, and follow the quick replacement instruction or manual available on website.
Is there any installation manual included?
The quick replacement guide is available on this page for download at any time. If you have any questions about the replacement, please feel free to contact us for help at service@honsva.com
Tips for New Installed parts.
Warranty: 1 Year
1. Follow the Quick Guide instructions available on official website to get a successful replacement.
2. A tip seal replacement is easy to perform, takes about 30 minutes, and uses only common tools (not included).
3. Run pump for about 40 hours (highly recommended) after finishing the replacement for optimum performance, as pumps with newly installed tip seals may require several days of operation to seat properly and achieve desired pressure and pumping speed.